ADS7100 ULTRASCOPE Dual Channel Oscilloscope & Multimeter

ADS7100 ULTRASCOPE Dual Channel Oscilloscope & Multimeter is a high speed of Dual Channel Oscilloscope & Multimeter which can test automotive oscilloscope for specialists.

UKOBD2 Provide top quality ADS7100 ULTRASCOPE Dual Channel Oscilloscope & Multimeter, if you need ADS7100 ULTRASCOPE Dual Channel Oscilloscope & Multimeter, or have any questions about ADS7100 ULTRASCOPE Dual Channel Oscilloscope & Multimeter, welcome to contact us.

Wholesale Top quality VAS6154, GM Tech2, VCM II For Ford, Porsche Piwis III, USB Link 2, Scania VCI3, CAN Clip, wiTech MicroPod 2, T300 key programmer, locksmith tools

images of ADS7100 ULTRASCOPE Dual Channel Oscilloscope & Multimeter


ADS7100 ULTRASCOPE Dual Channel Oscilloscope & Multimeter

Features:


1. Super fast Oscilloscope, high-accuracy multimeter.
2. OBD2 BUS analyzer for CAN, SAEJ1850, ISO9141.
3. Real time screen refresh rates.
4. Small size, light weight, portable.
5. Dual channel, auto calibration, auto trigger.
6. Auto screen horizontal axis, perpendicular division.
7. Low battery voltage charge indicator.
8. Maximum input voltage: 600V peak DC or AC.
9. UI3111, CSA C22.2 No. 1010-1 safety standards compliance.
10. Generic OBDII diagnostics.

Specifications:

Language: English
Material: Metal
Color: Blue+black
Weight: 7.5KG
Display screen: 320*240 CCFL backlit LCD
Save model: Reference ware form saved
Connect: USB interface with PC

Sample Rate 25 Ms/s(Dual CH mode)
50 Ms/s(Single CH mode)
Record Length 512 in single shot mode
256 in all other modes
Sample/Division 25
Update Rate Real time
Modes Single shot,Roll,Normal
Accuracy 0.01%
Sweep Rate 1uS to 5S in 1,2,5 sequence

Vertical

Bandwidth 1MHz
Resolution 8 Bit
Channels Dual
Coupling AC,DC
Input Impedance 1 MΩ
Accuracy 3%
Max input Voltage DC or AC 600vrms
Volt/Division 0.5mV to 500V in 1,2,5 in sequence
50mV to 50kV for ignition Secondary

Triggering

Source Internal, External
Coupling AC, DC
Slope Rising Or Falling edge
Trig Sensitivity 2/20 Division

Other

Waveform Memory 8 Shot
Reference Waveform 4S Shot
Ignition Analyzer Primary & Secondary Ignition
Conventional and DLI/DIS
Peak Voltage,Burn time & Voltage

DC V

Range Resolution Accuracy Impedance
5V 0.001V ±(0.3%+3) 1MΩ
50V 0.01V
500V 0.1V ±(0.5%+5)
1000V 1V

AC V

Range Resolution Accuracy Impedance
50-450Hz 0.45-5kHz 5kHz-20kHz
3V 0.001V ±(0.3%+3) ±(0.75%+5) ±(2%+5) 1MΩ
30V 0.01V
300V 0.1V ±(0.5%+5)
750V 1V N/A

OHM

Range Resolution Accuracy Over Load Protection
5kΩ 0.001kΩ ±(0.5%+5) 600V DC or AC rms
50kΩ 0.01kΩ
500kΩ 0.1kΩ
5MΩ 0.001MΩ ±(0.75%+10)

Continuity Test(Buzzer)

Test Voltage Threshold Over Load Protection
1.7V 100Digits 600VDC Or AC Peak

Optional Function

Temperature 0-200℃(Max 300℃)
Pressure 0-50Kg/Cm2
Ampere 0-4Amp, 0-40Amp, 0-400Amp

General Specifications

Operating Temp 0℃-50℃(32"F-122"F)humidity 75% or less
Power Supply Ni-MH 4.8V
Battery Life Time 3hours without backlit/2hours backlit ON
Display Type 320×240 LCD(CCFL backlit)
Dimensions 164mm(width)×58mm(depth)×256mm(height)
Weight 1kg

Package including:

1pc x Body
1pc x adaptor recharger
2pc x Probe cable
2pc x Needle cable
1pc x Ignition CYL.1 pickup probe
1pc x Battery cable
1pc x Aux. cigarette cable
1pc x User manual
1pc x Carry bag
1pc x Box enclosure


Go to Buy: ADS7100 ULTRASCOPE Dual Channel Oscilloscope & Multimeter

Tags: ads7100, ultrascope , dual channel , oscilloscope , multimeter
Prev: Manual EPROM Eraser Can erase 15 chips
Next: V-CHECKER A612 Auto Trip Computer Buy SC267 Instead